EN RU CN

Воспользуйтесь нашим инструментом для поиска

Наш инструмент расширенного поиска позволяет найти продукцию, в точности соответствующую вашим требованиям.

оронавирус COVID–19: Информация для клиентов касательно коронавируса COVID-19

E1W CIEL | Industrial Cable GlandFor all types of Steel & Aluminium Wire Armoured Cables

Double Seal Industrial Cast Integral Earth Lug Cable Gland

• External earth connection
• IThird party short circuit tested
• Metal-to-metal armour clamping
• Direct & remote installation
• Permanently crimped, low impedance earth termination
• Secure against self-loosening
• Displacement type inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Deluge protection option
• -60˚C to +130˚C
• EMC tested

Note: The Symmetrical Fault Current (kA) rating for 1 second applicable to the Cast Integral Earth Lug featured in the E1W CIEL products are as follows:
• 26.0 kA for Cable Gland sizes up to 40
• 43.0 kA for Cable Gland sizes 50S and above.

BS 6121:Part 1:1989, IEC 62444, EN 62444
Impact = Level 8, Retention = Class D
IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Category C
POCC GB.ГБ05.H00187
LRS: 01/00171 (E1), ABS: 16-LD1472056-PDA
IP66 as standard (IP67, IP68 available upon request)
Brass, Electroless Nickel Plated Brass, Aluminium
CMP Thermoset Rubber
Single Wire Armour (SWA), Aluminium Wire Armour (AWA)
Detachable Armour Cone & AnyWay Universal Clamping Ring
CMP Inner Displacement Seal & Unique CMP ‘LRS’ TM Outer Load Retention Seal
Cable Inner Bedding & Outer Cable Sheath

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings

Certificates

Нажмите здесь to view Certificates

Таблица выбора продукции

Нажмите здесь чтобы ознакомиться с технической иллюстрацией

Техническая иллюстрация

Нажмите здесь чтобы просмотреть информацию о заказе

Cable Gland SizeAvailable Entry Threads "C" (Alternate Metric Thread Lengths Available)Cable Bedding Diameter "A"Overall Cable Diameter "B"Armour RangeAcross Flats "D"Across Corners "D"Protrusion Length "F"Nominal Radius DimensionCIEL Earth Bolt SizeEarth Fault Current Rating (kA)Combined Ordering Reference (*Brass Metric)Cable Gland Weight (Ozs)
StandardOption
MetricThread Length (Metric) "E"NPTThread Length (Metric) "E"NPTMinMaxMinMaxminMaxMaxMax"H""G"SizeTypeOrdering Suffix
20SM200.3941/2”"0.7833/4”"0.2400.4570.3740.6260.0310.0490.9451.0392.7561.1261.520M82620SE1WC1RA6.878
20M200.3941/2”"0.7833/4”"0.2560.5470.4920.8230.0310.0491.2011.3232.8741.2521.646M82620E1WC1RA9.736
25SM250.3943/4”"0.7951”"0.4370.7830.5510.8660.0490.0631.4761.6263.5041.5002.000M82625SE1WC1RA15.450
25M250.3943/4”"0.7951”"0.4370.7830.7171.0310.0490.0631.4761.6263.5041.5002.000M82625E1WC1RA15.344
32M320.3941”"0.9841 1/4”"0.6691.0310.9331.3350.0630.0791.8111.9923.3861.6262.126M102632E1WC1RA17.849
40M400.5911 1/4”"1.0081 1/2”"0.8661.2641.0981.5910.0630.0792.1652.3823.5432.0002.689M122640E1WC1RA28.290
50SM500.5911 1/2”"1.0282”"1.1611.5001.3861.8390.0790.0982.3622.5983.5832.2522.937M124350SE1WC1RA31.147
50M500.5912”"1.0592 1/2”"1.4021.7321.5912.0870.0790.0982.7603.0353.7402.3743.126M124350E1WC1RA36.614
63SM630.5912”"1.0592 1/2”"1.5791.9651.7952.3390.0790.0982.9533.2484.0162.7563.563M124363SE1WC1RA57.708
63M630.5912 1/2”"1.5713”"1.8582.2012.1502.5910.0790.0983.1503.4654.0942.7563.563M124363E1WC1RA56.333
75SM750.5912 1/2”"1.5713”"2.0792.4372.3232.8350.0790.0983.5433.8984.5283.0003.878M124375SE1WC1RA81.483
75M750.5913”"1.6343 1/2”"2.3272.6732.6263.0870.0980.1183.9374.3314.6063.2524.252M124375E1WC1RA95.839
90M900.9453 1/2”"1.6854”"2.6223.0943.0003.5550.1240.1574.5004.9495.7873.7525.004M124390E1WC1RA155.805
100M1000.9454”"1.7325”"2.9923.5793.3903.9920.1240.1574.8435.3275.5124.0165.268M1243100E1WC1RA170.021
115M1150.9454”"1.7325”"3.3863.8543.9964.3390.1240.1575.2525.7766.3783.7525.004M1243115E1WC1RA218.381
130M1300.9455”"1.8436”"3.8194.5244.3394.8500.1240.1576.0006.5986.9694.0165.268M1243130E1WC1RA301.205
DIMENSIONS ARE DISPLAYED IN INCHES UNLESS OTHERWISE STATED
Cable Gland SizeAvailable Entry Threads "C" (Alternate Metric Thread Lengths Available)Cable Bedding Diameter "A"Overall Cable Diameter "B"Armour RangeAcross Flats "D"Across Corners "D"Protrusion Length "F"Radius DimensionCIEL Earth Bolt SizeEarth Fault Current Rating (kA)Combined Ordering Reference (*Brass Metric)Cable Gland Weight (Kgs)
StandardOption
MetricThread Length (Metric) "E"NPTThread Length (Metric) "E"NPTMinMaxMinMaxminMaxMaxMax"H""G"SizeTypeOrdering Suffix
20SM2010.01/2”"19.93/4”"6.111.69.515.90.81.2524.026.470.028.638.6M826.020SE1WC1RA0.195
20M2010.01/2”"19.93/4”"6.513.912.520.90.81.2530.533.673.031.841.8M826.020E1WC1RA0.276
25SM2510.03/4”"20.21”"11.119.914.022.01.251.637.541.389.038.150.8M826.025SE1WC1RA0.438
25M2510.03/4”"20.21”"11.119.918.226.21.251.637.541.389.038.150.8M826.025E1WC1RA0.435
32M3210.01”"25.01 1/4”"17.026.223.733.91.62.046.050.686.041.354.0M1026.032E1WC1RA0.506
40M4015.01 1/4”"25.61 1/2”"22.032.127.940.41.62.055.060.590.050.868.3M1226.040E1WC1RA0.802
50SM5015.01 1/2”"26.12”"29.538.135.246.72.02.560.066.091.057.274.6M1243.050SE1WC1RA0.883
50M5015.02”"26.92 1/2”"35.644.040.453.02.02.570.177.195.060.379.4M1243.050E1WC1RA1.038
63SM6315.02”"26.92 1/2”"40.149.945.659.42.02.575.082.5102.070.090.5M1243.063SE1WC1RA1.636
63M6315.02 1/2”"39.93”"47.255.954.665.82.02.580.088.0104.070.090.5M1243.063E1WC1RA1.597
75SM7515.02 1/2”"39.93”"52.861.959.072.02.02.590.099.0115.076.298.5M1243.075SE1WC1RA2.310
75M7515.03”"41.53 1/2”"59.167.966.778.42.53.0100.0110.0117.082.6108.0M1243.075E1WC1RA2.717
90M9024.03 1/2”"42.84”"66.678.676.290.33.154.0114.3125.7147.095.3127.1M1243.090E1WC1RA4.417
100M10024.04”"44.05”"76.090.986.1101.43.154.0123.0135.3140.0102.0133.8M1243.0100E1WC1RA4.820
115M11524.04”"44.05”"86.097.9101.5110.23.154.0133.4146.7162.095.3127.1M1243.0115E1WC1RA6.191
130M13024.05”"46.86”"97.0114.9110.2123.23.154.0152.4167.6177.0102.0133.8M1243.0130E1WC1RA8.539
DIMENSIONS ARE DISPLAYED IN MILLIMETRES UNLESS OTHERWISE STATED