оронавирус COVID–19: Информация для клиентов касательно коронавируса COVID-19
Наш инструмент расширенного поиска позволяет найти продукцию, в точности соответствующую вашим требованиям.
оронавирус COVID–19: Информация для клиентов касательно коронавируса COVID-19
Internationally Approved, Ex e, Explosive Atmosphere Cable Gland
• -20˚C to 200˚C high temperature ThermEx seals
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Displacement type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Internationally marked, IECEx & ATEX
• EMC tested
BS 6121:Part 1:1989, IEC 62444, EN 62444 | |
Impact = Level 8, Retention = Class D | |
IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only | |
Category B (Category A when used with braid, tape or pliable wire armour cables) | |
CML 18ATEX1323X | |
II 2G, II 1D, Ex e IIC Gb, Ex ta IIIC Da | |
EN 60079-0,7,31 | |
IECEx CML 18.0180X | |
Ex e IIC Gb, Ex ta IIIC Da | |
IEC 60079-0,7,31 | |
-20°C to +200°C | |
IP66, IP67 & IP68 ** | |
DTS01 : 91 | |
Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium | |
CMP SOLO LSF Halogen Free Thermoset Elastomer | |
Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Wire Braid Armour (e.g. SWB), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Armoured & Jacketed | |
Reversible Armour Cone & AnyWay Universal Clamping Ring | |
Unique CMP ‘LRS’ Outer Seal (Load Retention Seal) | |
Cable Outer Sheath |
* Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
Нажмите здесь чтобы ознакомиться с технической иллюстрацией
Нажмите здесь чтобы просмотреть информацию о заказе
Cable Gland Size | Available Entry Threads "C" (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter "A" | Overall Cable Diameter "B" | Armour Range | Across Flats "D" | Across Corners "D" | Protrusion Length "F" | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
||||||||||
Standard | Option | Grooved Cone (X) | Stepped Cone (W) | |||||||||||||||||
Metric | Thread Length (Metric) "E" | NPT | Thread Length (NPT) "E" | NPT | Max | Min | Max | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20s16 | M20 | 0.591 | 1/2" | 0.783 | 3/4" | 0.343 | 0.240 | 0.516 | 0.012 | 0.039 | 0.031 | 0.049 | 1.201 | 1.323 | 2.559 | 20S16 | C2KHT | 1RA | PVC06 | 8.113 |
20S | M20 | 0.591 | 1/2" | 0.783 | 3/4" | 0.461 | 0.374 | 0.626 | 0.012 | 0.039 | 0.031 | 0.049 | 1.201 | 1.323 | 2.441 | 20S | C2KHT | 1RA | PVC06 | 8.466 |
20 | M20 | 0.591 | 1/2" | 0.783 | 3/4" | 0.551 | 0.492 | 0.823 | 0.016 | 0.039 | 0.031 | 0.049 | 1.201 | 1.323 | 2.480 | 20 | C2KHT | 1RA | PVC06 | 8.113 |
25S | M25 | 0.591 | 3/4" | 0.795 | 1" | 0.787 | 0.551 | 0.866 | 0.016 | 0.047 | 0.049 | 0.063 | 1.476 | 1.626 | 2.736 | 25S | C2KHT | 1RA | PVC09 | 12.346 |
25 | M25 | 0.591 | 3/4" | 0.795 | 1" | 0.787 | 0.717 | 1.031 | 0.016 | 0.047 | 0.049 | 0.063 | 1.476 | 1.626 | 2.736 | 25 | C2KHT | 1RA | PVC09 | 12.346 |
32 | M32 | 0.591 | 1" | 0.984 | 1 1/4" | 1.024 | 0.933 | 1.335 | 0.016 | 0.047 | 0.063 | 0.079 | 1.811 | 1.992 | 2.953 | 32 | C2KHT | 1RA | PVC11 | 19.401 |
40 | M40 | 0.591 | 1 1/4" | 1.008 | 1 1/2" | 1.268 | 1.098 | 1.591 | 0.016 | 0.063 | 0.063 | 0.079 | 2.165 | 2.382 | 2.953 | 40 | C2KHT | 1RA | PVC15 | 26.456 |
50S | M50 | 0.591 | 1 1/2" | 1.028 | 2" | 1.504 | 1.386 | 1.839 | 0.016 | 0.063 | 0.079 | 0.098 | 2.362 | 2.598 | 3.031 | 50S | C2KHT | 1RA | PVC18 | 30.336 |
50 | M50 | 0.591 | 2" | 1.059 | 2 1/2" | 1.736 | 1.591 | 2.087 | 0.024 | 0.063 | 0.079 | 0.098 | 2.760 | 3.035 | 3.031 | 50 | C2KHT | 1RA | PVC21 | 39.860 |
63S | M63 | 0.591 | 2" | 1.059 | 2 1/2" | 1.969 | 1.795 | 2.339 | 0.024 | 0.063 | 0.079 | 0.098 | 2.953 | 3.248 | 3.150 | 63S | C2KHT | 1RA | PVC23 | 39.860 |
63 | M63 | 0.591 | 2 1/2" | 1.571 | 3" | 2.205 | 2.150 | 2.591 | 0.024 | 0.063 | 0.079 | 0.098 | 3.150 | 3.465 | 3.150 | 63 | C2KHT | 1RA | PVC25 | 47.267 |
75S | M75 | 0.591 | 2 1/2" | 1.571 | 3" | 2.441 | 2.323 | 2.835 | 0.024 | 0.063 | 0.079 | 0.098 | 3.543 | 3.898 | 3.425 | 75S | C2KHT | 1RA | PVC28 | 71.253 |
75 | M75 | 0.591 | 3" | 1.634 | 3 1/2" | 2.528 | 2.626 | 3.087 | 0.024 | 0.063 | 0.098 | 0.118 | 3.937 | 4.331 | 3.465 | 75 | C2KHT | 1RA | PVC30 | 87.480 |
90 | M90 | 0.945 | 3 1/2" | 1.685 | 4" | 3.094 | 3.000 | 3.555 | 0.031 | 0.063 | 0.124 | 0.157 | 4.528 | 4.980 | 4.016 | 90 | C2KHT | 1RA | PVC32 | 124.164 |
100 | M100 | 0.945 | 4" | 1.732 | 5" | 3.583 | 3.390 | 3.992 | 0.031 | 0.063 | 0.124 | 0.157 | 5.000 | 5.500 | 4.488 | 100 | C2KHT | 1RA | LSF33 | 161.555 |
115 | M115 | 0.945 | 4" | 1.732 | 5" | 3.858 | 3.996 | 4.339 | 0.031 | 0.063 | 0.124 | 0.157 | 5.252 | 5.776 | 4.488 | 115 | C2KHT | 1RA | LSF34 | 229.281 |
130 | M130 | 0.945 | 5" | 1.842 | - | 4.528 | 4.339 | 4.850 | 0.031 | 0.063 | 0.124 | 0.157 | 6.000 | 6.598 | 4.488 | 130 | C2KHT | 1RA | LSF35 | 299.829 |
Cable Gland Size | Available Entry Threads "C" (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter "A" | Overall Cable Diameter "B" | Armour Range | Across Flats "D" | Across Corners "D" | Protrusion Length "F" | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
||||||||||
Standard | Option | Grooved Cone (X) | Stepped Cone (W) | |||||||||||||||||
Metric | Thread Length (Metric) "E" | NPT | Thread Length (NPT) "E" | NPT | Max | Min | Max | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20s16 | M20 | 15.0 | 1/2" | 19.9 | 3/4" | 8.7 | 6.1 | 13.1 | 0.3 | 1.0 | 0.8 | 1.3 | 30.5 | 33.6 | 65.0 | 20S16 | C2KHT | 1RA | PVC06 | 0.23 |
20S | M20 | 15.0 | 1/2" | 19.9 | 3/4" | 11.7 | 9.5 | 15.9 | 0.3 | 1.0 | 0.8 | 1.3 | 30.5 | 33.6 | 62.0 | 20S | C2KHT | 1RA | PVC06 | 0.24 |
20 | M20 | 15.0 | 1/2" | 19.9 | 3/4" | 14.0 | 12.5 | 20.9 | 0.4 | 1.0 | 0.8 | 1.3 | 30.5 | 33.6 | 63.0 | 20 | C2KHT | 1RA | PVC06 | 0.23 |
25S | M25 | 15.0 | 3/4" | 20.2 | 1" | 20.0 | 14.0 | 22.0 | 0.4 | 1.2 | 1.3 | 1.6 | 37.5 | 41.3 | 69.5 | 25S | C2KHT | 1RA | PVC09 | 0.35 |
25 | M25 | 15.0 | 3/4" | 20.2 | 1" | 20.0 | 18.2 | 26.2 | 0.4 | 1.2 | 1.3 | 1.6 | 37.5 | 41.3 | 69.5 | 25 | C2KHT | 1RA | PVC09 | 0.35 |
32 | M32 | 15.0 | 1" | 25.0 | 1 1/4" | 26.0 | 23.7 | 33.9 | 0.4 | 1.2 | 1.6 | 2.0 | 46.0 | 50.6 | 75.0 | 32 | C2KHT | 1RA | PVC11 | 0.55 |
40 | M40 | 15.0 | 1 1/4" | 25.6 | 1 1/2" | 32.2 | 27.9 | 40.4 | 0.4 | 1.6 | 1.6 | 2.0 | 55.0 | 60.5 | 75.0 | 40 | C2KHT | 1RA | PVC15 | 0.75 |
50S | M50 | 15.0 | 1 1/2" | 26.1 | 2" | 38.2 | 35.2 | 46.7 | 0.4 | 1.6 | 2.0 | 2.5 | 60.0 | 66.0 | 77.0 | 50S | C2KHT | 1RA | PVC18 | 0.86 |
50 | M50 | 15.0 | 2" | 26.9 | 2 1/2" | 44.1 | 40.4 | 53.0 | 0.6 | 1.6 | 2.0 | 2.5 | 70.1 | 77.1 | 77.0 | 50 | C2KHT | 1RA | PVC21 | 1.13 |
63S | M63 | 15.0 | 2" | 26.9 | 2 1/2" | 50.0 | 45.6 | 59.4 | 0.6 | 1.6 | 2.0 | 2.5 | 75.0 | 82.5 | 80.0 | 63S | C2KHT | 1RA | PVC23 | 1.13 |
63 | M63 | 15.0 | 2 1/2" | 39.9 | 3" | 56.0 | 54.6 | 65.8 | 0.6 | 1.6 | 2.0 | 2.5 | 80.0 | 88.0 | 80.0 | 63 | C2KHT | 1RA | PVC25 | 1.34 |
75S | M75 | 15.0 | 2 1/2" | 39.9 | 3" | 62.0 | 59.0 | 72.0 | 0.6 | 1.6 | 2.0 | 2.5 | 90.0 | 99.0 | 87.0 | 75S | C2KHT | 1RA | PVC28 | 2.02 |
75 | M75 | 15.0 | 3" | 41.5 | 3 1/2" | 64.2 | 66.7 | 78.4 | 0.6 | 1.6 | 2.5 | 3.0 | 100.0 | 110.0 | 88.0 | 75 | C2KHT | 1RA | PVC30 | 2.48 |
90 | M90 | 24.0 | 3 1/2" | 42.8 | 4" | 78.6 | 76.2 | 90.3 | 0.8 | 1.6 | 3.2 | 4.0 | 115.0 | 126.5 | 102.0 | 90 | C2KHT | 1RA | PVC32 | 3.52 |
100 | M100 | 24.0 | 4" | 44.0 | 5" | 91.0 | 86.1 | 101.4 | 0.8 | 1.6 | 3.2 | 4.0 | 127.0 | 139.7 | 114.0 | 100 | C2KHT | 1RA | LSF33 | 4.58 |
115 | M115 | 24.0 | 4" | 44.0 | 5" | 98.0 | 101.5 | 110.2 | 0.8 | 1.6 | 3.2 | 4.0 | 133.4 | 146.7 | 114.0 | 115 | C2KHT | 1RA | LSF34 | 6.50 |
130 | M130 | 24.0 | 5" | 46.8 | - | 115.0 | 110.2 | 123.2 | 0.8 | 1.6 | 3.15 | 4.0 | 152.4 | 167.6 | 114.0 | 130 | C2KHT | 1RA | LSF35 | 8.50 |