EN RU CN

Воспользуйтесь нашим инструментом для поиска

Наш инструмент расширенного поиска позволяет найти продукцию, в точности соответствующую вашим требованиям.

оронавирус COVID–19: Информация для клиентов касательно коронавируса COVID-19

BWL CIEL | Industrial Cable GlandFor all types of Steel & Aluminium Wire Armoured Cables

Heavy Duty Industrial Cast Integral Earth Lug Cable Gland

• External earth connection
• Third party short circuit tested
• Metal-to-metal armour clamping
• Direct & remote installation
• Robust, heavy duty design
• Permanently crimped, low impedance earth termination
• Secure against self-loosening
• Longer body protects armour wires from impact
• -60˚C to +200˚C
• EMC tested

Note: The Symmetrical Fault Current (kA) rating for 1 second applicable to the Cast Integral Earth Lug featured in the BWL CIEL products are as follows:
• 26.0 kA for Cable Gland sizes up to 40
• 43.0 kA for Cable Gland sizes 50S and above.

 

BS 6121 : Part 1 : 1989
Impact = Level 8, Retention = Class B
IK10 to IEC 62262 (20 joules)
Category C
POCC.GB.HA46.H00140
LRS: 01/00171 (E1), ABS: 16-LD1472056-PDA
IP2X
Brass, Electroless Nickel Plated Brass
Single Wire Armour (SWA), Aluminium Wire Armour (AWA)
Armour Cone & AnyWay Universal Clamping Ring

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings

As IEC 62444 and EN 62444 do not cover cable glands which are supplied without cable sealing rings, the information provided here is for information only, since this product does not fully conform to these standards.

Certificates

Нажмите здесь to view Certificates

Таблица выбора продукции

Нажмите здесь чтобы ознакомиться с технической иллюстрацией

Техническая иллюстрация

Нажмите здесь чтобы просмотреть информацию о заказе

Cable Gland SizeAvailable Entry Threads "C" (Alternate Metric Thread Lengths Available)Cable Bedding Diameter "A"Overall Cable Diameter "B"Armour RangeAcross Flats "D"Across Corners "D"Protrusion Length "F"Nominal Radius DimensionCIEL Earth Bolt SizeEarth Fault Current Rating (kA)Combined Ordering Reference (*Brass Metric)Cable Gland Weight (Ozs)
Standard
MetricThread Length (Metric) "E"MaxMaxMinMaxMaxMax"H""G"SizeTypeOrdering Suffix
20SM200.3940.4610.6260.0310.0490.9451.0391.2681.1261.520M82620SBWLC1RA3.951
20M200.3940.5510.8230.0310.0491.2011.3231.2051.2521.646M82620BWLC1RA5.573
25M250.3940.7871.0310.0490.0631.4761.6261.4331.5002.000M82625BWLC1RA7.901
32M320.3941.0311.3350.0630.0791.8111.9921.2831.6262.126M82632BWLC1RA8.607
40M400.5911.2681.5910.0630.0792.1652.3821.4532.0002.689M102640BWLC1RA18.977
50SM500.5911.5041.8390.0790.0982.3622.5981.5592.2522.937M124350SBWLC1RA23.634
50M500.5911.7362.0910.0790.0982.7603.0351.5392.3743.126M124350BWLC1RA25.327
63SM630.5911.9692.3390.0790.0982.9533.2482.0472.7563.563M124363SBWLC1RA43.246
63M630.5912.2052.5940.0790.0983.1503.4651.9612.7563.563M124363BWLC1RA41.553
75SM750.5912.4412.8390.0790.0983.5433.8982.5083.0003.878M124375SBWLC1RA65.574
75M750.5912.6773.0910.0980.1183.9374.3312.2563.2524.252M124375BWLC1RA72.453
90M900.9453.1103.5590.1240.1574.5004.9492.5983.7524.252M124390BWLC1RA103.212
100M1000.9453.5433.9960.1240.1574.8435.3273.1504.0005.500M1243100BWLC1RA106.951
115M1150.9453.8584.3430.1240.1575.2525.7763.8584.4095.453M1243115BWLC1RA143.424
130M1300.9454.5284.8540.1240.1576.0006.5984.3314.4095.453M1243130BWLC1RA185.012
Dimensions are displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads "C" (Alternate Metric Thread Lengths Available)Cable Bedding Diameter "A"Overall Cable Diameter "B"Armour RangeAcross Flats "D"Across Corners "D"Protrusion Length "F"Nominal Radius DimensionCIEL Earth Bolt SizeEarth Fault Current Rating (kA)Combined Ordering Reference (*Brass Metric)Cable Gland Weight (Kgs)
Standard
MetricThread Length (Metric) "E"MaxMaxMinMaxMaxMax"H""G"SizeTypeOrdering Suffix
20SM2010.011.715.90.81.2524.026.432.228.638.6M826.020SBWLC1RA0.112
20M2010.014.020.90.81.2530.533.630.631.841.8M826.020BWLC1RA0.158
25M2510.020.026.21.251.637.541.336.438.150.8M826.025BWLC1RA0.224
32M3210.026.233.91.62.046.050.632.641.354.0M826.032BWLC1RA0.244
40M4015.032.240.41.62.055.060.536.950.868.3M1026.040BWLC1RA0.538
50SM5015.038.246.72.02.560.066.039.657.274.6M1243.050SBWLC1RA0.670
50M5015.044.153.12.02.570.177.139.160.379.4M1243.050BWLC1RA0.718
63SM6315.050.059.42.02.575.082.552.070.090.5M1243.063SBWLC1RA1.226
63M6315.056.065.92.02.580.088.049.870.090.5M1243.063BWLC1RA1.178
75SM7515.062.072.12.02.590.099.063.776.298.5M1243.075SBWLC1RA1.859
75M7515.068.078.52.53.0100.0110.057.382.6108.0M1243.075BWLC1RA2.054
90M9024.079.090.43.154.0114.3125.766.095.3108.0M1243.090BWLC1RA2.926
100M10024.090.0101.53.154.0123.0135.380.0101.6139.7M1243.0100BWLC1RA3.032
115M11524.098.0110.33.154.0133.4146.798.0112.0138.5M1243.0115BWLC1RA4.066
130M13024.0115.0123.33.154.0152.4167.6110.0112.0138.5M1243.0130BWLC1RA5.245
Dimensions are displayed in millimetres unless otherwise stated