EN RU CN

Воспользуйтесь нашим инструментом для поиска

Наш инструмент расширенного поиска позволяет найти продукцию, в точности соответствующую вашим требованиям.

оронавирус COVID–19: Информация для клиентов касательно коронавируса COVID-19

CX | Industrial Cable GlandFor Braid, Pliable Wire & Steel Tape Armoured Cables

Single Seal Industrial Cable Gland

• High quality durable materials
• Robust, heavy duty design
• Metal-to-metal armour clamping
• Direct & remote installation
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60˚C to +130˚C (standard), -20˚C to 200˚C (ThermIn option CXHT)
• Deluge protection option
• EMC tested

† Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).

Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below

BS 6121:Part 1:1989, IEC 62444, EN 62444
Impact = Level 8, Retention = Class D
IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Category A
POCC GB.ГБ05.H00187
LRS: 01/00171 (E1), ABS: 16-LD1472056-PDA
IP66 as standard (IP67, IP68 available upon request)
Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
CMP Thermoset Rubber
Wire Braid Armour, Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel Tape Armour (STA)
Detachable Armour Cone & AnyWay Universal Clamping Ring
Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Cable Outer Sheath
Cable Gland kit for use with all types of cable includes 2 Brass Cable Glands, 2 Steel Locknuts, 2 Brass Earth Tags and 2 PVC Shrouds for sizes up to and including 32mm. For sizes 40mm and above each kit includes 1 of each component.

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings

Certificates

Нажмите здесь to view Certificates

Таблица выбора продукции

Нажмите здесь чтобы ознакомиться с технической иллюстрацией

Техническая иллюстрация

Нажмите здесь чтобы просмотреть информацию о заказе

Cable Gland SizeAvailable Entry Threads “"C”" (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“"A”"
Overall
Cable
Diameter
“"B”"
Armour Range †
Grooved Cone (X)
Across
Flats “"D”"
Across
Corners
“"D”"
Protrusion
Length "“F"”
Combined Ordering Reference
(Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
MetricThread Length
(Metric) “"E”"
MaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.3940.3430.2400.5160.0120.0390.9451.0391.89020S16CX1RAPVC043.527
20SM200.3940.4610.3740.6260.0120.0390.9451.0391.89020SCX1RAPVC043.527
20M200.3940.5510.4920.8230.0160.0391.2011.3231.89020CX1RAPVC065.185
25SM250.3940.7870.5510.8660.0160.0471.4761.6262.20525SCX1RAPVC097.901
25M250.3940.7870.7171.0310.0160.0471.4761.6262.20525CX1RAPVC097.796
32M320.3941.0350.9331.3350.0160.0471.8111.9922.12632CX1RAPVC1110.794
40M400.5911.2681.0981.5910.0160.0632.1652.3822.28340CX1RAPVC1515.803
50SM500.5911.5041.3861.8390.0160.0632.3622.5982.40250SCX1RAPVC1820.000
50M500.5911.7361.5912.0870.0240.0632.7603.0352.36250CX1RAPVC2126.491
63SM630.5911.9691.7952.3390.0240.0632.9533.2482.91363SCX1RAPVC2336.544
63M630.5912.2052.1502.5910.0240.0633.1503.4652.79563CX1RAPVC2535.838
75SM750.5912.4412.3232.8350.0240.0633.5433.8983.38675SCX1RAPVC2863.035
75M750.5912.6772.6263.0870.0240.0633.9374.3313.22875CX1RAPVC3073.758
90M900.9453.1503.0003.5550.0310.0634.5004.9493.74090CX1RAPVC32107.374
100M1000.9453.5833.3903.9920.0310.0634.8435.3273.740100CX1RALSF33110.478
115M1150.9453.8583.9964.3390.0310.0635.2525.7764.232115CX1RALSF34157.886
130M1300.9454.5284.3394.8500.0310.0636.0006.5984.331130CX1RALSF35203.214
Cable Gland SizeAvailable Entry Threads “"C”" (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“"A”"
Overall
Cable
Diameter
“"B”"
Armour Range †
Grooved Cone (X)
Across
Flats "“D”"
Across
Corners
“"D”"
Protrusion
Length “"F”"
Combined Ordering Reference
(Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
MetricThread Length
(Metric) "“E”"
MaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2010.08.76.113.10.31.024.026.448.020S16CX1RAPVC040.100
20SM2010.011.79.515.90.31.024.026.448.020SCX1RAPVC040.100
20M2010.014.012.520.90.41.030.533.648.020CX1RAPVC060.147
25SM2510.020.014.022.00.41.237.541.356.025SCX1RAPVC090.224
25M2510.020.018.226.20.41.237.541.356.025CX1RAPVC090.221
32M3210.026.323.733.90.41.246.050.654.032CX1RAPVC110.306
40M4015.032.227.940.40.41.655.060.558.040CX1RAPVC150.448
50SM5015.038.235.246.70.41.660.066.061.050SCX1RAPVC180.567
50M5015.044.140.453.00.61.670.177.160.050CX1RAPVC210.751
63SM6315.050.045.659.40.61.675.082.574.063SCX1RAPVC231.036
63M6315.056.054.665.80.61.680.088.071.063CX1RAPVC251.016
75SM7515.062.059.072.00.61.690.099.086.075SCX1RAPVC281.787
75M7515.068.066.778.40.61.6100.0110.082.075CX1RAPVC302.091
90M9024.080.076.290.30.81.6114.3125.795.090CX1RAPVC323.044
100M10024.091.086.1101.40.81.6123.0135.395.0100CX1RALSF333.132
115M11524.098.0101.5110.20.81.6133.4146.7107.5115CX1RALSF344.476
130M13024.0115.0110.2123.20.81.6152.4167.6110.0130CX1RALSF355.761