Falcon2BC Plastic

The CMP Products Falcon Two Bolt single cable cleat is a non-metallic cable cleat which has been designed, constructed, and tested in accordance with the International Standard ‘cable cleats for Electrical Installations’ (IEC 61914:2009). It ensures the retention and securing of single cables, without damaging or deforming the cable. The cable cleat is manufactured from various materials making it suitable for both indoor and outdoor applications. Due to its unique twin arc internal patent pending design profile it exhibits excellent retention, limiting both the axial and lateral movement. The Falcon Two Bolt cable cleats have an excellent range take and are suitable for cable diameters of 38mm up to 135mm in only eight sizes. This cable cleat has two M12 clearance holes for securing it to a mounting surface, which allows for either M10 or M12 fasteners to be used.

  • Third party certification to IEC 61914:2009
  • Available in Nylon, Low Smoke & Fume (LSF) V0 Nylon & LUL approved polymer
  • Sunlight (UV) & weather resistant
  • Operating temperature -40°C to +60°C
  • Can be double stacked
  • 38 – 135mm in 8 sizes
  • Excellent axial & lateral load retention
  • Two bolt fixing design
Short Circuit Testing to IEC 61914:2009 - Clause 9.5
Multicore FormationParallel Formation
Two short circuits (6.4.4) 600mm fixed cleat centresOne short circuit (6.4.3) 600mm fixed cleat centres 105mm cable centresTwo short circuits (6.4.4) 600mm fixed cleat centres 105mm cable centres
0.1 sec0.1 sec0.1 sec
76kA Peak110kA Peak86kA Peak
36.2kA RMS50.0kA RMS40.9kA RMS
Type 6.1.2. Non Metallic 2BC - Two Bolt Cable Cleat
IEC 61914:2009
-40°C to +60°C
IEC 61914:2009 clause / part 6.2
Pass - 120 second flame application time
IEC 61914:2009 clause
10.0, 10.1, IEC 60695-11-5
16kN - 26kN, IEC 61914:2009 clause 9.3
2.75kN - 5kN, IEC 61914:2009 clause 9.4
Pass - Very Heavy
IEC 61914:2009 clause 6.3, 6.3.5, 9.2
Pass - IEC 61914:2009 clause 6.5.1.2, 11.1
Nylon, V0 nylon & LUL approved polymer
Black

**For lateral and axial load ratings or Short circuit ratings of LUL polymer products, please contact CMP.

Таблица выбора продукции

Нажмите здесь чтобы ознакомиться с технической иллюстрацией

Техническая иллюстрация

Falcon Part No.Cable Ø range take (in.)Dimensions (in.)Weight
W *(LUL +5%)
(Oz.)
WHDPFixing Hole Ø
2BC0380481.496 - 1.8903.7802.9132.40265 - 692 x M10 / M124.37
2BC0480581.890 - 2.2834.2133.3072.40276 - 802 x M10 / M125.15
2BC0580702.283 - 2.7564.6853.8192.40288 - 922 x M10 / M126.21
2BC0700832.756 - 3.2685.2364.3312.402102 - 1062 x M10 / M127.44
2BC0830973.268 - 3.8195.7874.8822.402116 - 1202 x M10 / M128.54
2BC0961093.780 - 4.2916.2995.3542.402129 - 1332 x M10 / M129.74
2BC1061204.173 - 4.7246.7725.8272.402141 - 1452 x M10 / M1210.93
2BC1201354.724 - 5.3157.3626.4172.402156 - 1602 x M10 / M1212.31
Falcon Part No.Cable Ø range take (mm)Dimensions mmWeight
W *(LUL +5%)
(g)
WHDPFixing Hole Ø
2BC03804838 - 4896.074.061.065 - 692 x M10 / M12124
2BC04805848 - 58107.084.061.076 - 802 x M10 / M12146
2BC05807058 - 70119.097.061.088 - 922 x M10 / M12176
2BC07008370 - 83133.0110.061.0102 - 1062 x M10 / M12211
2BC08309783 - 97147.0124.061.0116 - 1202 x M10 / M12242
2BC09610996 - 109160.0136.061.0129 - 1332 x M10 / M12276
2BC106120106 - 120172.0148.061.0141 - 1452 x M10 / M12310
2BC120135120 - 135187.0163.061.0156 - 1602 x M10 / M12349