- Home
- Cable Glands
- Products
- Group I Mining
- PXSS2KHCREX | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Barrier Cable Gland
- Ex nR
- Ex ta
PXSS2KHCREX | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Barrier Cable Gland For all types of Unarmoured & Braid cables housed in Flexible Hose
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
Globally Approved, Explosive Atmosphere RapidEx Barrier Cable Gland
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Direct & remote installation
• Superior levels of cable retention
• Displacement type environmental seal
• Designed to prevent Coldflow
• Deluge protected
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22
• Globally marked, IECEx, ATEX & cCSAus
Patent granted: DE 2287986, ES 2287986, FR 2287986, IT 2287986, NL 2287986, NO 2287986, TR 2287986, AU 2010284848, AU 2014274614, CA 2771713, GB 2485114, MY 153846, SG 178839, US 8872027, US 9484133, US 9774178
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class B |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
ATEX Certificate | CML 18ATEX1325X, CML 18ATEX4317X |
UKEX Certificate | CML 21UKEX1214X, CML 21UKEX4215X |
Code of Protection | II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb |
Compliance Standards | EN 60079-0,1,7,15,31 |
IECEx Certificate | IECEx CML 18.0182X |
Code of Protection | Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb |
Compliance Standards | IEC 60079-0,1,7,15,31 |
EAC Certificate (Formerly GOST R, K & B) | C-GB.A07.B.04595/22 |
CCOE / PESO (India) Certificate | Ex d: P548696, Ex e: P533772 Ex nR: P548695 |
NEPSI Certificate | GYJ18.1252X |
INMETRO Approval | TÜV 12.2073X |
RETIE Approval | 03866 |
UkrSEPRO | CU 19.0371X |
Marine Approvals | LRS: 01/00172, ABS: 20-LD1948801-PDA |
Ingress Protection Rating ** | IP66, IP67 & IP68 |
Deluge Protection Compliance | DTS01 : 91 |
Cable Gland Material | Electroless Nickel Plated Brass, Brass, Stainless Steel, Aluminium |
Seal Material | CMP SOLO LSF Halogen Free Thermoset Elastomer / RapidEx Barrier Compound |
Cable Type | Unarmoured |
Armour Clamping | Detachable Resin Tube / Cone & AnyWay Universal Clamping Ring |
Sealing Technique | Unique CMP ‘LRS’ Outer Seal (Load Retention Seal) |
Sealing Area(s) | RapidEx Resin Barrier & Cable Outer Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Minimum Entry Thread (Metric) 'C' | Minimum Thread Length 'E' | Diameter Over Conductors 'A' | Max Number of Cores | Overall Cable Diameter 'B' | Nominal Hose Bore Ø 'H' | Across Flats 'D' | Across Corners 'D' | Nominal * Protrusion Length Without Hose Connection 'F' | Hose Connection Length 'G' | Overall Length 'E' + 'F' + 'G' * | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
|||
Min | Max | Max | Max | Size | Type | Ordering Suffix |
|||||||||||
20S16 | M20 | 0.59 | 0.34 | 21 | 0.12 | 0.34 | 0.51 | 1.18 | 1.30 | 2.01 | 0.63 | 3.25 | 20S16 | PXSS2KREXHC13 | 1RA | PVC06 | 7.76 |
20S16 | M20 | 0.59 | 0.34 | 21 | 0.12 | 0.34 | 0.63 | 1.18 | 1.30 | 2.01 | 0.63 | 3.25 | 20S16 | PXSS2KREXHC16 | 1RA | PVC06 | 7.76 |
20S | M20 | 0.59 | 0.46 | 21 | 0.24 | 0.46 | 0.63 | 1.18 | 1.30 | 1.94 | 0.63 | 3.25 | 20S | PXSS2KREXHC16 | 1RA | PVC06 | 7.76 |
20 | M20 | 0.59 | 0.50 | 21 | 0.26 | 0.55 | 0.75 | 1.18 | 1.30 | 1.97 | 0.79 | 3.42 | 20 | PXSS2KREXHC19 | 1RA | PVC06 | 7.76 |
25 | M25 | 0.59 | 0.69 | 30 | 0.44 | 0.79 | 0.98 | 1.42 | 1.56 | 2.18 | 1.06 | 3.89 | 25 | PXSS2KREXHC25 | 1RA | PVC09 | 12.70 |
32 | M32 | 0.59 | 0.93 | 50 | 0.67 | 1.04 | 1.26 | 1.61 | 1.78 | 2.19 | 1.30 | 4.14 | 32 | PXSS2KREXHC32 | 1RA | PVC10 | 15.87 |
40 | M40 | 0.59 | 1.18 | 59 | 0.87 | 1.26 | 1.50 | 1.97 | 2.17 | 2.22 | 1.61 | 4.49 | 40 | PXSS2KREXHC38 | 1RA | PVC13 | 22.93 |
50S | M50 | 0.59 | 1.44 | 89 | 1.16 | 1.50 | 2.01 | 2.36 | 2.60 | 2.26 | 2.13 | 5.06 | 50S | PXSS2KREXHC51 | 1RA | PVC18 | 37.74 |
50 | M50 | 0.59 | 1.61 | 115 | 1.40 | 1.73 | 2.01 | 2.36 | 2.60 | 2.45 | 2.13 | 5.20 | 50 | PXSS2KREXHC51 | 1RA | PVC18 | 33.51 |
63S | M63 | 0.59 | 1.89 | 115 | 1.58 | 1.96 | 2.48 | 2.76 | 3.04 | 2.48 | 2.76 | 5.91 | 63S | PXSS2KREXHC63 | 1RA | PVC21 | 61.02 |
63 | M63 | 0.59 | 2.11 | 115 | 1.86 | 2.20 | 2.48 | 2.95 | 3.25 | 2.56 | 2.76 | 6.01 | 63 | PXSS2KREXHC63 | 1RA | PVC23 | 50.44 |
75S | M75 | 0.59 | 2.36 | 140 | 2.08 | 2.44 | 2.99 | 3.17 | 3.48 | 2.58 | 3.60 | 6.87 | 75S | PXSS2KREXHC76 | 1RA | PVC26 | 88.19 |
75 | M75 | 0.59 | 2.53 | 140 | 2.33 | 2.67 | 2.99 | 3.35 | 3.68 | 2.51 | 3.60 | 6.98 | 75 | PXSS2KREXHC76 | 1RA | PVC27 | 69.14 |
Dimensions displayed in inches unless otherwise stated |
Cable Gland Size | Minimum Entry Thread (Metric) 'C' | Minimum Thread Length 'E' | Diameter Over Conductors 'A' | Max Number of Cores | Overall Cable Diameter 'B' | Nominal Hose Bore Ø 'H' | Across Flats 'D' | Across Corners 'D' | Nominal * Protrusion Length Without Hose Connection 'F' | Hose Connection Length 'G' | Max Overall length E+F+G | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||
Min | Max | Max | Max | Size | Type | Ordering Suffix |
|||||||||||
20S16 | M20 | 15.0 | 8.6 | 21 | 3.1 | 8.6 | 13.0 | 30.0 | 33.0 | 51.1 | 16.0 | 82.5 | 20S16 | PXSS2KREXHC13 | 1RA | PVC06 | 0.22 |
20S16 | M20 | 15.0 | 8.6 | 21 | 3.1 | 8.6 | 16.0 | 30.0 | 33.0 | 51.1 | 16.0 | 82.5 | 20S16 | PXSS2KREXHC16 | 1RA | PVC06 | 0.22 |
20S | M20 | 15.0 | 11.7 | 21 | 6.1 | 11.7 | 16.0 | 30.0 | 33.0 | 49.3 | 16.0 | 82.5 | 20S | PXSS2KREXHC16 | 1RA | PVC06 | 0.22 |
20 | M20 | 15.0 | 12.6 | 21 | 6.5 | 14.0 | 19.0 | 30.0 | 33.0 | 50.0 | 20.0 | 86.9 | 20 | PXSS2KREXHC19 | 1RA | PVC06 | 0.22 |
25 | M25 | 15.0 | 17.5 | 30 | 11.1 | 20.0 | 25.0 | 36.0 | 39.6 | 55.3 | 27.0 | 98.8 | 25 | PXSS2KREXHC25 | 1RA | PVC09 | 0.36 |
32 | M32 | 15.0 | 23.6 | 50 | 17.0 | 26.3 | 32.0 | 41.0 | 45.1 | 55.6 | 33.0 | 105.2 | 32 | PXSS2KREXHC32 | 1RA | PVC10 | 0.45 |
40 | M40 | 15.0 | 30.0 | 59 | 22.0 | 32.1 | 38.0 | 50.0 | 55.0 | 56.3 | 41.0 | 114.1 | 40 | PXSS2KREXHC38 | 1RA | PVC13 | 0.65 |
50S | M50 | 15.0 | 36.6 | 89 | 29.5 | 38.2 | 51.0 | 60.0 | 66.0 | 57.3 | 54.0 | 128.5 | 50S | PXSS2KREXHC51 | 1RA | PVC18 | 1.07 |
50 | M50 | 15.0 | 41.0 | 115 | 35.6 | 44.0 | 51.0 | 60.0 | 66.0 | 62.2 | 54.0 | 132.1 | 50 | PXSS2KREXHC51 | 1RA | PVC18 | 0.95 |
63S | M63 | 15.0 | 47.9 | 115 | 40.1 | 49.9 | 63.0 | 70.1 | 77.1 | 63.0 | 70.0 | 150.1 | 63S | PXSS2KREXHC63 | 1RA | PVC21 | 1.73 |
63 | M63 | 15.0 | 53.7 | 115 | 47.2 | 55.9 | 63.0 | 75.0 | 82.5 | 65.0 | 70.0 | 152.6 | 63 | PXSS2KREXHC63 | 1RA | PVC23 | 1.43 |
75S | M75 | 15.0 | 59.9 | 140 | 52.8 | 61.9 | 76.0 | 80.4 | 88.4 | 65.6 | 91.5 | 174.6 | 75S | PXSS2KREXHC76 | 1RA | PVC26 | 2.50 |
75 | M75 | 15.0 | 64.3 | 140 | 59.1 | 67.9 | 76.0 | 85.0 | 93.5 | 63.7 | 91.5 | 177.4 | 75 | PXSS2KREXHC76 | 1RA | PVC27 | 1.96 |
Dimensions displayed in millimeters unless otherwise stated |
CMP Products Cable Gland Identification
Apart from the customary product, and certification (where it is required) marking, CMP Products also provides easy identification indicators to ensure that the correct cable gland is used in the correct environment.
Read moreCMP Products Barrier Cable Glands
Although the various different types of cable glands with integral barrier seal may be covered by certification classifying them as Flameproof type ‘d’ (Ex d), users should be aware of the differences in how the technique is achieved as this could affect the subsequent installation, maintenance and inspection of them in future.
Read moreCable Entries Made Directly into Flameproof Type ‘d’ (Ex d)
The following page contains an illustrative example of Cable Entries Made Directly into Flameproof Type 'd' (Ex d).
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now