Triton CDS PB (T3CDSPB) | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Lead Sheathed Armoured Cables
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
Globally Approved, Explosive Atmosphere Cable Gland
• Effectively earths / grounds lead sheathed cables
• Fully sequential, three step installation procedure
• Direct & remote installation
• Unique compensating displacement seal system (CDS)
– Metal-to-metal installation every time regardless of lead sheath diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX, UL & cCSAus
• Superior EMC Performance
† Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).
Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below. Stepped (W) Cone is suitable for Single Wire Armour (SWA), or Aluminium Wire Armour (AWA) cables.
For under / oversized armour wires click here
Patents granted: DE 1077517, FR 1077517, GB 1077517
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class D |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
Electrical Classifications * | Category B (Category A when used with braid, tape or pliable wire armour cables) |
ATEX Certificate | CML 18ATEX1326X CML 18ATEX4318X |
UKEX Certificate | "CML 21UKEX1258X,CML 21UKEX4259X" |
Code of Protection | II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da, II 3G Ex nR IIC Gc, I M2, Ex db I Mb, Ex eb I Mb |
Compliance Standards | EN60079-0,1,7,15,31 |
IECEx Certificate | IECEx CML 18.0183X |
Code of Protection | Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb |
Compliance Standards | IEC 60079-0,1,7,15,31 |
ECAS Certificate | 20-02-05626 |
EAC Certificate | C-GB.AД07.B.04599/22 |
CCC Certificate | 2020322313002527 |
CCOE / PESO (India) Certificate | Ex d: P548696, Ex e: P533772 Ex nR: P548695 |
INMETRO Certificate | TÜV 11.0374X |
RETIE Certificate | 03866 |
UkrSEPRO | CU 19.0371X |
Marine Approvals | LRS: 01/00172 (E3), DNV: TAE00000Y, ABS: 20-LD1948801-PDA, BV: 43180/A1BV |
Ingress Protection Rating ** | IP66, IP67 & IP68 |
Deluge Protection Compliance | DTS01 : 91 |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel |
Seal Material | CMP SOLO LSF Halogen Free Thermoset Elastomer |
Cable Type | Lead Sheathed & Single Wire Armour (LC/SWA), Lead Sheathed & Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour (LC/SWB), Lead Sheathed & Pliable Wire Armour (LC/PWA), Lead Sheathed & Steel Tape Armour (LC/STA), Lead Sheathed & Aluminium Strip Armour (LC/ASA) |
Armour Clamping | Reversible Armour Cone & AnyWay Universal Clamping Ring |
Sealing Technique | Inner Bedding Sealing Ring: Compensating Displacement Seal (CDS), Outer Sheath Sealing Ring : Load Retention Seal (LRS) |
Sealing Area(s) | Cable Inner Bedding & Outer Cable Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners |
Note: * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Lead Sheath Diameter 'A' | Overall Cable Diameter 'B' | Armour Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||||||||
Standard | Option | Grooved Cone (X) | Stepped Cone (W) | ||||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Min | Max | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 0.59 | ½' | 0.78 | ¾" | 0.12 | 0.31 | 0.24 | 0.52 | 0.01 | 0.04 | 0.03 | 0.05 | 0.94 | 1.04 | 3.10 | 20S16 | T3CDSPB | 1RA | PVC36 | 7.05 |
20S | M20 | 0.59 | ½' | 0.78 | ¾" | 0.24 | 0.43 | 0.37 | 0.63 | 0.01 | 0.04 | 0.03 | 0.05 | 0.94 | 1.04 | 3.10 | 20S | T3CDSPB | 1RA | PVC36 | 7.05 |
20 | M20 | 0.59 | ½' | 0.78 | ¾" | 0.26 | 0.53 | 0.49 | 0.82 | 0.02 | 0.04 | 0.03 | 0.05 | 1.20 | 1.32 | 3.00 | 20 | T3CDSPB | 1RA | PVC06 | 9.88 |
25S | M25 | 0.59 | ¾' | 0.80 | 1" | 0.44 | 0.76 | 0.55 | 0.87 | 0.02 | 0.05 | 0.05 | 0.06 | 1.48 | 1.63 | 3.50 | 25S | T3CDSPB | 1RA | PVC09 | 15.52 |
25 | M25 | 0.59 | ¾' | 0.80 | 1" | 0.44 | 0.76 | 0.72 | 1.03 | 0.02 | 0.05 | 0.05 | 0.06 | 1.48 | 1.63 | 3.49 | 25 | T3CDSPB | 1RA | PVC09 | 15.52 |
32 | M32 | 0.59 | 1' | 0.98 | 1 ¼" | 0.67 | 1.00 | 0.93 | 1.33 | 0.02 | 0.05 | 0.06 | 0.08 | 1.81 | 1.99 | 3.57 | 32 | T3CDSPB | 1RA | PVC11 | 22.58 |
40 | M40 | 0.59 | 1 ¼' | 1.01 | 1 ½" | 0.87 | 1.23 | 1.10 | 1.59 | 0.02 | 0.06 | 0.06 | 0.08 | 2.17 | 2.38 | 3.67 | 40 | T3CDSPB | 1RA | PVC15 | 32.10 |
50S | M50 | 0.59 | 1 ½' | 1.03 | 2" | 1.16 | 1.46 | 1.39 | 1.84 | 0.02 | 0.06 | 0.08 | 0.10 | 2.36 | 2.60 | 3.96 | 50S | T3CDSPB | 1RA | PVC18 | 39.86 |
50 | M50 | 0.59 | 2' | 1.06 | 2 ½" | 1.40 | 1.68 | 1.59 | 2.09 | 0.02 | 0.06 | 0.08 | 0.10 | 2.76 | 3.04 | 4.17 | 50 | T3CDSPB | 1RA | PVC21 | 56.79 |
63S | M63 | 0.59 | 2' | 1.06 | 2 ½" | 1.58 | 1.91 | 1.80 | 2.34 | 0.02 | 0.06 | 0.08 | 0.10 | 2.95 | 3.25 | 4.04 | 63S | T3CDSPB | 1RA | PVC23 | 61.38 |
63 | M63 | 0.59 | 2 ½' | 1.57 | 3" | 1.86 | 2.13 | 2.15 | 2.59 | 0.02 | 0.06 | 0.08 | 0.10 | 3.15 | 3.46 | 4.15 | 63 | T3CDSPB | 1RA | PVC25 | 63.14 |
75S | M75 | 0.59 | 2 ½' | 1.57 | 3" | 2.08 | 2.37 | 2.32 | 2.83 | 0.02 | 0.06 | 0.08 | 0.10 | 3.54 | 3.90 | 4.35 | 75S | T3CDSPB | 1RA | PVC28 | 91.01 |
75 | M75 | 0.59 | 3' | 1.63 | 3 ½" | 2.33 | 2.57 | 2.63 | 3.09 | 0.02 | 0.06 | 0.10 | 0.12 | 3.94 | 4.33 | 4.74 | 75 | T3CDSPB | 1RA | PVC30 | 117.82 |
90 | M90 | 0.94 | 3 ½' | 1.69 | 4" | 2.62 | 3.04 | 3.00 | 3.56 | 0.03 | 0.06 | 0.12 | 0.16 | 4.53 | 4.98 | 5.47 | 90 | T3CDSPB | 1RA | PVC32 | 172.49 |
100 | M100 | 0.94 | 3 ½' | 1.69 | 4" | 2.99 | 3.47 | 3.39 | 3.99 | 0.03 | 0.06 | 0.12 | 0.16 | 5.00 | 5.50 | 5.05 | 100 | T3CDSPB | 1RA | LSF33 | 176.02 |
115 | M115 | 0.94 | 4" | 1.73 | 5" | 3.39 | 3.70 | 4.00 | 4.34 | 0.03 | 0.06 | 0.12 | 0.16 | 5.43 | 5.98 | 6.35 | 115 | T3CDSPB | 1RA | LSF34 | 273.37 |
130 | M130 | 0.94 | 5" | 1.84 | - | 3.82 | 4.33 | 4.34 | 4.85 | 0.03 | 0.06 | 0.12 | 0.16 | 6.18 | 6.80 | 6.82 | 130 | T3CDSPB | 1RA | LSF35 | 346.04 |
Dimensions are displayed in inches unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Lead Sheath Diameter 'A' | Overall Cable Diameter 'B' | Armour Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||||||||
Standard | Option | Grooved Cone (X) | Stepped Cone (W) | ||||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Min | Max | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 15.0 | ½' | 19.9 | ¾" | 3.1 | 7.8 | 6.1 | 13.1 | 0.3 | 1.0 | 0.8 | 1.25 | 24.0 | 26.4 | 78.7 | 20S16 | T3CDSPB | 1RA | PVC36 | 0.20 |
20S | M20 | 15.0 | ½' | 19.9 | ¾" | 6.1 | 11.0 | 9.5 | 15.9 | 0.3 | 1.0 | 0.8 | 1.25 | 24.0 | 26.4 | 78.7 | 20S | T3CDSPB | 1RA | PVC36 | 0.20 |
20 | M20 | 15.0 | ½' | 19.9 | ¾" | 6.5 | 13.4 | 12.5 | 20.9 | 0.4 | 1.0 | 0.8 | 1.25 | 30.5 | 33.6 | 76.2 | 20 | T3CDSPB | 1RA | PVC06 | 0.28 |
25S | M25 | 15.0 | ¾' | 20.2 | 1" | 11.1 | 19.3 | 14.0 | 22.0 | 0.4 | 1.2 | 1.3 | 1.6 | 37.5 | 41.3 | 88.8 | 25S | T3CDSPB | 1RA | PVC09 | 0.44 |
25 | M25 | 15.0 | ¾' | 20.2 | 1" | 11.1 | 19.3 | 18.2 | 26.2 | 0.4 | 1.2 | 1.3 | 1.6 | 37.5 | 41.3 | 88.7 | 25 | T3CDSPB | 1RA | PVC09 | 0.44 |
32 | M32 | 15.0 | 1' | 25.0 | 1 ¼" | 17.0 | 25.5 | 23.7 | 33.9 | 0.4 | 1.2 | 1.6 | 2.0 | 46.0 | 50.6 | 90.7 | 32 | T3CDSPB | 1RA | PVC11 | 0.64 |
40 | M40 | 15.0 | 1 ¼' | 25.6 | 1 ½" | 22.0 | 31.2 | 27.9 | 40.4 | 0.4 | 1.6 | 1.6 | 2.0 | 55.0 | 60.5 | 93.2 | 40 | T3CDSPB | 1RA | PVC15 | 0.91 |
50S | M50 | 15.0 | 1 ½' | 26.1 | 2" | 29.5 | 37.2 | 35.2 | 46.7 | 0.4 | 1.6 | 2.0 | 2.5 | 60.0 | 66.0 | 100.7 | 50S | T3CDSPB | 1RA | PVC18 | 1.13 |
50 | M50 | 15.0 | 2' | 26.9 | 2 ½" | 35.6 | 42.6 | 40.4 | 53.0 | 0.6 | 1.6 | 2.0 | 2.5 | 70.1 | 77.1 | 105.8 | 50 | T3CDSPB | 1RA | PVC21 | 1.61 |
63S | M63 | 15.0 | 2' | 26.9 | 2 ½" | 40.1 | 48.5 | 45.6 | 59.4 | 0.6 | 1.6 | 2.0 | 2.5 | 75.0 | 82.5 | 102.5 | 63S | T3CDSPB | 1RA | PVC23 | 1.74 |
63 | M63 | 15.0 | 2 ½' | 39.9 | 3" | 47.2 | 54.2 | 54.6 | 65.8 | 0.6 | 1.6 | 2.0 | 2.5 | 80.0 | 88.0 | 105.4 | 63 | T3CDSPB | 1RA | PVC25 | 1.79 |
75S | M75 | 15.0 | 2 ½' | 39.9 | 3" | 52.8 | 60.2 | 59.0 | 72.0 | 0.6 | 1.6 | 2.0 | 2.5 | 90.0 | 99.0 | 110.6 | 75S | T3CDSPB | 1RA | PVC28 | 2.58 |
75 | M75 | 15.0 | 3' | 41.5 | 3 ½" | 59.1 | 65.2 | 66.7 | 78.4 | 0.6 | 1.6 | 2.5 | 3.0 | 100.0 | 110.0 | 120.3 | 75 | T3CDSPB | 1RA | PVC30 | 3.34 |
90 | M90 | 24.0 | 3 ½' | 42.8 | 4" | 66.6 | 77.1 | 76.2 | 90.3 | 0.8 | 1.6 | 3.2 | 4.0 | 115.0 | 126.5 | 138.9 | 90 | T3CDSPB | 1RA | PVC32 | 4.89 |
100 | M100 | 24.0 | 3 ½' | 42.8 | 4" | 76.0 | 88.1 | 86.1 | 101.4 | 0.8 | 1.6 | 3.2 | 4.0 | 127.0 | 139.7 | 128.2 | 100 | T3CDSPB | 1RA | LSF33 | 4.99 |
115 | M115 | 24.0 | 4" | 44.0 | 5" | 86.0 | 94.1 | 101.5 | 110.2 | 0.8 | 1.6 | 3.2 | 4.0 | 138.0 | 151.8 | 161.3 | 115 | T3CDSPB | 1RA | LSF34 | 7.75 |
130 | M130 | 24.0 | 5" | 46.8 | - | 97.0 | 110.1 | 110.2 | 123.2 | 0.8 | 1.6 | 3.2 | 4.0 | 157.0 | 172.7 | 173.3 | 130 | T3CDSPB | 1RA | LSF35 | 9.81 |
Dimensions are displayed in millimetres unless otherwise stated |
ATEX Responsibilities
When placing cable glands or similar equipment on the market, manufacturers should provide a Declaration of Conformity confirming that its products are identical to the samples originally type tested by the Ex Notified body, and that they meet the Essential Health & Safety Requirements of the Directive 2014/34/EU.
Read moreThe Galvanic Series
A set of values has been given to a series of metals and alloys in terms of their relative nobility, or ability to resist corrosion, whilst immersed in sea water. In other situations, where materials are not immersed, but are exposed to atmospheric contaminants, their status will be largely dependent upon the environment in which they are located.
Read moreLead Covered / Lead Sheathed Cables
In addition to the standard requirements for SWA cables, there is a set of special guidelines for lead covered cables intended for direct burial in the ground of hydrocarbons processing and refinery sites. These guidelines were introduced in the UK by the Oil Companies Material Association (OCMA) and responsibility for these were subsequently transferred to EEMUA, the Engineering Equipment and Material Users Association.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now