A2FRC | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Unarmoured & Braid Armour Cables housed in Conduit
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
Globally Approved, Rigid & Flexible Conduit Explosive Atmosphere Cable Gland
• Designed for rigid & flexible conduits
• Easy install running coupler design
• Displacement type flameproof seal
• -60°C to +130°C
• Globally marked, IECEx, ATEX & CSA
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Cable Anchorage = Class B |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
ATEX Certificate | CML 18ATEX1321X, CML 18ATEX4313X |
UKEX Certificate | "CML 21UKEX1245X,CML 21UKEX4246X" |
Code of Protection | II 2G II 1D Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da , II 3G Ex nR IIC Gc |
Compliance Standards | EN 60079-0,1,7,15,31 |
IECEx Certificate | IECEx CML 18.0179X |
Code of Protection | Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da |
Compliance Standards | IEC 60079-0,1,7,15,31 |
CSA Certificate | 1211841 |
Code of Protection | Ex d IIC, Ex e II, Ex nR II, Enclosure Type 4x |
Compliance Standards | C22.2 No 0,0.4, 94,174, CAN/CSA-E60079-0,1,7, 15 |
EAC Certificate | C-GB.A07.B.02519/20 |
KCS Certificate | 19-AV4B0-0471X 19-AV4B0-0472X 19-AV4B0-0473X |
CCOE / PESO (India) Certificate | Ex d: P548696, Ex e: P533772 Ex nR: P548695 |
CCC Certificate | 2020322313002951 |
INMETRO Approval | TÜV 21.1075X |
RETIE Approval | 03866 |
UkrSEPRO | CU 19.0371X |
SANS | IA S-XPL21804 21.0008X |
Marine Approvals | LRS: 01/00173, DNV: TAE00000Y, 17-LD1619350-PDA, BV: 43180/A1 BV, |
Ingress Protection Rating ** | IP66 |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel |
Seal Material | CMP SOLO LSF Halogen Free Thermoset Elastomer |
Cable Type | Unarmoured & Braided when terminated inside enclosure |
Sealing Technique | CMP Unique Displacement Seal Concept |
Sealing Area(s) | Cable Outer Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners |
ECAS Certificate | E23-02-065446 |
*Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
**When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Female Connection Thread 'G' | Female Connection Thread (NPT) 'G' | Overall Cable Diameter 'A' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric male and female) | Shroud | Cable Gland Weight (Ozs) |
|||||||
Standard | Option | ||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||||
20S16 | M20 | 0.59 | ½' | 0.78 | ¾" | M20 | ½' | 0.13 | 0.34 | 0.94 | 1.04 | 1.85 | 20S16 | A2FRC | 1RA | PVC04 | 3.88 |
20S | M20 | 0.59 | ½' | 0.78 | ¾" | M20 | ½' | 0.24 | 0.46 | 0.94 | 1.04 | 1.81 | 20S | A2FRC | 1RA | PVC04 | 3.88 |
20 | M20 | 0.59 | ½' | 0.78 | ¾" | M20 | ½' | 0.26 | 0.55 | 1.06 | 1.17 | 1.89 | 20 | A2FRC | 1RA | PVC05 | 3.88 |
25 | M25 | 0.59 | ¾' | 0.80 | 1" | M25 | ¾' | 0.44 | 0.79 | 1.42 | 1.56 | 2.21 | 25 | A2FRC | 1RA | PVC09 | 7.05 |
32 | M32 | 0.59 | 1' | 0.98 | 1 ¼" | M32 | 1' | 0.67 | 1.04 | 1.61 | 1.78 | 2.19 | 32 | A2FRC | 1RA | PVC10 | 8.47 |
40 | M40 | 0.59 | 1 ¼' | 1.01 | 1 ½" | M40 | 1 ¼' | 0.93 | 1.27 | 1.97 | 2.17 | 2.27 | 40 | A2FRC | 1RA | PVC13 | 11.64 |
50S | M50 | 0.59 | 1 ½' | 1.03 | 2" | M50 | 1 ½' | 1.22 | 1.50 | 2.17 | 2.38 | 2.33 | 50S | A2FRC | 1RA | PVC15 | 15.17 |
50 | M50 | 0.59 | 2' | 1.06 | 2 ½" | M50 | 2' | 1.40 | 1.73 | 2.36 | 2.60 | 2.53 | 50 | A2FRC | 1RA | PVC18 | 15.52 |
63S | M63 | 0.59 | 2' | 1.06 | 2 ½" | M63 | 2' | 1.63 | 1.96 | 2.78 | 3.06 | 2.43 | 63S | A2FRC | 1RA | PVC21 | 25.40 |
63 | M63 | 0.59 | 2 ½' | 1.57 | 3" | M63 | 2 ½' | 1.86 | 2.20 | 2.95 | 3.25 | 2.80 | 63 | A2FRC | 1RA | PVC23 | 22.58 |
75S | M75 | 0.59 | 2 ½' | 1.57 | 3" | M75 | 2 ½' | 2.13 | 2.44 | 3.31 | 3.64 | 2.76 | 75S | A2FRC | 1RA | PVC26 | 33.86 |
75 | M75 | 0.59 | 3' | 1.63 | 3 ½" | M75 | 3' | 2.41 | 2.67 | 3.31 | 3.64 | 2.88 | 75 | A2FRC | 1RA | PVC26 | 30.34 |
90 | M90 | 0.94 | 3 ½' | 1.69 | 4" | M90 | 3 ½' | 2.62 | 3.15 | 4.25 | 4.68 | 4.19 | 90 | A2FRC | 1RA | PVC31 | 79.37 |
Dimensions displayed in inches unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Female Connection Thread 'G' | Female Connection Thread (NPT) 'G' | Overall Cable Diameter 'A' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric male and female) | Shroud | Cable Gland Weight (Kgs) |
|||||||
Standard | Option | ||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||||
20S16 | M20 | 15.0 | ½' | 19.9 | ¾" | M20 | ½' | 3.2 | 8.7 | 24.0 | 26.4 | 46.9 | 20S16 | A2FRC | 1RA | PVC04 | 0.11 |
20S | M20 | 15.0 | ½' | 19.9 | ¾" | M20 | ½' | 6.1 | 11.7 | 24.0 | 26.4 | 46.1 | 20S | A2FRC | 1RA | PVC04 | 0.11 |
20 | M20 | 15.0 | ½' | 19.9 | ¾" | M20 | ½' | 6.5 | 14.0 | 27.0 | 29.7 | 47.9 | 20 | A2FRC | 1RA | PVC05 | 0.11 |
25 | M25 | 15.0 | ¾' | 20.2 | 1" | M25 | ¾' | 11.1 | 20.0 | 36.0 | 39.6 | 56.1 | 25 | A2FRC | 1RA | PVC09 | 0.20 |
32 | M32 | 15.0 | 1' | 25.0 | 1 ¼" | M32 | 1' | 17.0 | 26.3 | 41.0 | 45.1 | 55.5 | 32 | A2FRC | 1RA | PVC10 | 0.24 |
40 | M40 | 15.0 | 1 ¼' | 25.6 | 1 ½" | M40 | 1 ¼' | 23.5 | 32.2 | 50.0 | 55.0 | 57.7 | 40 | A2FRC | 1RA | PVC13 | 0.33 |
50S | M50 | 15.0 | 1 ½' | 26.1 | 2" | M50 | 1 ½' | 31.0 | 38.2 | 55.0 | 60.5 | 59.1 | 50S | A2FRC | 1RA | PVC15 | 0.43 |
50 | M50 | 15.0 | 2' | 26.9 | 2 ½" | M50 | 2' | 35.6 | 44.0 | 60.0 | 66.0 | 64.3 | 50 | A2FRC | 1RA | PVC18 | 0.44 |
63S | M63 | 15.0 | 2' | 26.9 | 2 ½" | M63 | 2' | 41.5 | 49.9 | 70.5 | 77.6 | 61.6 | 63S | A2FRC | 1RA | PVC21 | 0.72 |
63 | M63 | 15.0 | 2 ½' | 39.9 | 3" | M63 | 2 ½' | 47.2 | 55.9 | 75.0 | 82.5 | 71.0 | 63 | A2FRC | 1RA | PVC23 | 0.64 |
75S | M75 | 15.0 | 2 ½' | 39.9 | 3" | M75 | 2 ½' | 54.0 | 61.9 | 84.0 | 92.4 | 70.1 | 75S | A2FRC | 1RA | PVC26 | 0.96 |
75 | M75 | 15.0 | 3' | 41.5 | 3 ½" | M75 | 3' | 61.1 | 67.9 | 84.0 | 92.4 | 73.2 | 75 | A2FRC | 1RA | PVC26 | 0.86 |
90 | M90 | 24.0 | 3 ½' | 42.8 | 4" | M90 | 3 ½' | 66.6 | 79.9 | 108.0 | 118.8 | 106.3 | 90 | A2FRC | 1RA | PVC31 | 2.25 |
Dimensions displayed in millimeters unless otherwise stated |
Cable Gland Installation
The installation of equipment that is intended for use in explosive atmospheres must be carried out by competent personnel in line with good engineering practices, closely observing all of the applicable local legislation, following relevant manufacturers’ instructions and any conditions of certification.
Read moreHealth & Safety and the ATEX Directive
Operators and contractors must comply with regulations laid down to ensure the safety of workers and follow installation codes of practice that are designed to reduce risk. Under UK law, the Health & Safety at Work Act makes employers responsible for ensuring the health and safety of their employees and also of the public, if they are at risk from dangerous substances or situations. The Protection of Workers at Risk from Potentially Explosive Atmospheres Directive 99/92/EC establishes minimum requirements to protect workers against hazards from explosive atmospheres.
Read moreSheath Material Characteristics
Clause 9.3.2 of IEC 60079-14 permits cables with either thermoplastic, thermosetting or elastomeric sheath materials. Clause 9.3.1 of IEC 60079-14 requires cable inner or outer sheaths to have a tensile strength of 8.5 MPa. IEC 60079-14 permits the use of ‘thermoplastic’, ‘thermosetting’ and ‘elastomeric’ materials for the construction of cable bedding and sheathing. Examples of these materials and common identification types for cable sheathing, as defined by relevant standards.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.